#!/bin/sh
# This regression test is a part of SIPp.
# The BYE a UAC sends when its call aborts after an INFO from the UAS
# has the UAC's From and the UAS's To, not the INFO's From and To, and
# a CSeq above the UAC's re-INVITE (2), not the INFO's (1) + 1. The UAS
# only answers it with a 200 then.
. "`dirname "$0"`/../functions"; init

rm -f uas.log
sippfg -sf uas.xml -i 127.0.0.1 -p 25800 -m 1 -timeout 8 -timeout_error \
    -trace_msg -message_file uas.log >/dev/null 2>&1 &
job=$!
sleep 1
sippfg -sf uac.xml -i 127.0.0.1 -p 25801 -m 1 127.0.0.1:25800 \
    -timeout 8 >/dev/null 2>&1
wait $job
uas=$?
from=`sed -e '/^BYE /,/^$/!d;/^From:/!d;s/[[:cntrl:]]//g' uas.log`
to=`sed -e '/^BYE /,/^$/!d;/^To:/!d;s/[[:cntrl:]]//g' uas.log`
cseq=`sed -e '/^BYE /,/^$/!d;/^CSeq:/!d;s/[[:cntrl:]]//g' uas.log`
rm -f uas.log

case "$from/$to" in
"From: <sip:uac@"*";tag=uactag/To: <sip:uas@"*";tag=uastag")
    ;;
*)
    fail "got \"$from\" and \"$to\"";;
esac
test $uas -eq 0 || fail "the UAS did not answer the BYE with a 200 ($cseq)"
ok